Hitachi Air Cond - RA-10JF2 - Window Type with Cooling capacity

Wide Flow Type with Cooling capacity: 9,010 BTU/h
Blue NANO titanium air purifying filter
High cooling capacity & quiet operation
Auto swing
Green fin condenser


Model
RA-10JF2
Phase, Voltage, Frequency
ф , V, Hz
1 ф, 220-240V, 50Hz
Cooling Capacity
kW
2.64-2.64
BTU/h
9,010-9,010
Total Input
W
900-970
Total Amperes
A
4.2-4.2
EER
BTU/h-W
10.01-9.3
COP
2.93-2.72
Air Flow (H/M/L)
m ³/min
7.15
Dehumidifying Capacity
L/h
1.6
Sound Pressure Level
Indoor (H/M/L/SS)
dB
47/35
Outdoor (W/H/D)
dB
57/52
Net Dimension (W/H/D)
mm
470/345/610
Net Weight
kg
31
FEATURES
Remote Control
-
Fan Speed
2
Detachable & Washable Front Panel

Timer
-
Season Dry Operation
-
Pre Filter
Stainless
Air Purifying Filter
Blue Nano Titanium
Auto Swing (Left/Right)

Air Exhaust System

Drainless Splash System

Outdoor Heat Exchanger
Green fin

Thursday, December 20, 2007

LG Ceiling Convertible Type Air Cond HW-C306WSB0 2.5 hp


Model : HW-C306WSB02.5 hp 30,000 Btu/h

Capacity : 8.60kW
COOLING[Btu/hr] : 30,000
Electrical Data
VOLTAGE, FREQUENCY[Ø,V,Hz] : 1/220~240/50
Input-Cooling/Heating[W] : 3,250

Tuesday, December 18, 2007

VIVA All Kinds Of New, Reconditioned Chillers , Cooling Tower, Spare Parts


All Kinds Of New, Reconditioned Chillers , Cooling Tower, Spare Parts

A. Series PW Comprises :

1. Standard units designed for cooling only. Units that provide
heating or dehumidification are available on separate order.
2. Integral, packaged units designed for floor-standing installation.

B. Applications

Cooling of shops and stores, offices, restaurants, coffee shops,
movie theaters, supermarket, department stores, recreation,
facilities, schools, and so on.

C. Construction

These are compact units with the compressor, condenser,
evaporator and fans. Factory-assembled.
The refrigerant is charged at the factory, where all the necessary
tests and inspections are carried out.

D. Installation

1. This involves on-site connection of the cooling water and drain
plus provision of any ducts required.
2. With the provision of a primary power supply and installation of
instrumentation, Series PW air conditioners are ready to operate.

Address : 94 Batu 3, Jalan Cheras, 56100, Kuala Lumpur, Malaysia.Tel : + 6 03-92847373 Fax : + 6 03-92850397 Email: marketing@viva.com.my

Thursday, December 13, 2007

Hitachi RAS-10EX9S



RAS-10EX9S
Air Exchanger Type with Cooling capacity: 10,080 BTU/h
Super NANO titanium air
Air exchanger
UV fresh
Triple air purification system
Twin Air Flow
Speed Cool
Vertical and horizontal auto swing
Silent operation
High Energy efficiency
Green fin condenser
Reliable fuzzy logic control
Sleep mode timer
Auto restart
Temperature indicator
Flexible installation
Products Specification: -
Model
Indoor
RAS-10EX9S
Outdoor
RAC-10EX9
Phase, Voltage, Frequency
1 ф, 220-240V, 50Hz
Cooling Capacity
2.93-2.95 kW
10,000-10,080
BTU/h
Total Input
880-885 W
Total Amperes
4.10-3.80 A
EER
11.36-11.39 BTU/h-W
COP
3.33-3.33
Air Flow (H/M/L)
11.0/9.0/7.0 m ³/min
Dehumidifying Capacity
1.4 L/h
Sound Pressure Level
Indoor (H/M/L/SS)
40/34/26/- dB
Outdoor
48 dB
Net Dimensions
Indoor (W/H/D)
840/298/248 mm
Outdoor (W/H/D)
700/570/210 mm
Net Weight Indoor / Outdoor
15/26 kg
FEATURES
Handy Remote Control

Automatic Control System
Air Exchanger

Twin Air Flow

Fuzzy Logic Control

Flap Control

Fan Speed Control
3 Grades
Sleep Mode Control

Sensor Dry Operation

3-Minutes Delay Circuit

Econo-Dry Function

Timer
24 Hours
Washable Front Panel

Changeable Drain Hose

Air Purifying Filter
Super Nano Titanium
Triple Air Purification

UV Fresh

Outdoor Heat Exchanger
Green Fin
Maximum Length of Piping
10/5 m
Diameter for Pipe Gas / Liquid
9.52/6.35 mm
Recommended Consumer Price: RM 1529.00 (WM)

Saturday, October 20, 2007

Amazing House Sculpture Made Out of Dust!


This guy must had collected lots of dust to make these house sculpture.. I guess he took quite a long time to finish each one of these amazing house. See for yourself here ..

Art: Amazing House Made Out of Dust!

Monday, October 8, 2007

Altoids, the Powerful USB Charger for Apple iPod


iPod: Minty Boost, the Powerful USB Charger for Apple iPod This is a small & simple, but very , mp3 player, camera, cell phone, and just about any other gadget you can plug into a USB port to charge! Charges from 2 AA batteries. This version includes an attached USB to iPod dock connecter for easier carrying/storage for an additional price of $19.00
see more .. Altoids the Minty Boost, the Powerful USB Charger for Apple iPod

Tuesday, October 2, 2007

Health - Eating disorders

Eating disorders are often thought of as a problem of troubled teens or young women in college. But that's far from the only truth. Adults — even older adults — also can have eating disorders, whether it's anorexia, bulimia, binge-eating disorder or a nonspecific eating disorder.
Donald McAlpine, M.D., a psychiatrist and the director of the adult outpatient eating disorders services at Mayo Clinic, Rochester, Minn., treats people with eating disorders. Here, he discusses how eating disorders affect adult women.

The typical image of someone with an eating disorder is an adolescent girl or a young woman. But can adult women have eating disorders, too?
It's true that eating disorders usually affect younger women, peaking in the late teens or early 20s. However, eating disorders also affect woman in their 30s, 40s, 50s and beyond.
These women typically fall into three categories:
  • Women who have secretly struggled with an eating disorder their entire life without seeking treatment
  • Women who were treated for eating disorders when they were younger and develop a recurrence when they get older
  • Women who first develop an eating disorder as an adult
Are women more likely to have an eating disorder as an adult if they had one as a teen or young woman?
Most women who receive appropriate treatment get well enough that they no longer meet the criteria for being diagnosed with an eating disorder. However, many women will continue to have some degree of lingering signs or symptoms of an eating disorder that can flare up under stress. These may include bingeing and purging, such as vomiting, or renewed efforts to restrict eating with significant weight loss.
Are the characteristics of eating disorders different for women in their 30s and beyond?
There are several differences in eating disorders depending on age, including:
  • Common triggers. Young women with bulimia nervosa are often driven by excessive concern with weight, shape and body image. Older women, on the other hand, may be driven to binge and purge to cope with unpleasant mood stages. Of course, women at any age can struggle with poor body image, even women in their 60s and 70s. Eating disorders in women in their 40s and beyond are often triggered by such life events as the death of a loved one, divorce, remarriage, traumatic illness or signs of aging.
  • Denial. Denial is very common in younger women with anorexia nervosa but seems to be less common in older women. Older women may more readily acknowledge that an eating disorder is harming their life and seek help. Older women who are worn down by years of symptoms may also be more motivated to seek help. Motivation for change often leads to a more successful outcome in treating the illness.
  • Identity and coping. Years of daily eating disorder symptoms can become deeply engrained. Women who have had symptoms for years may ironically find it difficult to live without this eating disorder identity or coping style, as uncomfortable or emotionally painful as it may be.
  • Health effects. Eating disorders have dangerous health effects at any age. But older women — those in their 60s and beyond — are especially at risk. In fact, most people who die of the effects of anorexia are older than age 65 — not young girls. Older women with a long history of eating disorders may have developed much more serious health problems. In addition, they may have other health conditions that make them more vulnerable to problems from eating disorders.
How does the treatment for eating disorders of older women differ from that of younger women?
It's common for older women to tell me that when they were younger — and still in denial about their illness — that they bluffed their way through treatment. They would return to eating disorder behaviors as soon as they were done with treatment because they never truly were that motivated to overcome their eating disorder. Now older and wiser, these women may do better with treatment because they no longer have that youthful sense of immortality and they're more aware of the consequences of their disease, such as osteoporosis. For these reasons, they're often more motivated to overcome their eating disorder.
We still have a long way to go, but treatment programs have progressed substantially in the last two decades. Cognitive behavior therapy for eating disorders — focusing on self-monitoring, homework assignments and goal setting — was in its infancy in the early 1980s. Women treated for eating disorders in midlife may find that the treatment they had 20 years ago offers much greater benefit to them now. And since their initial treatment, new medications have been approved for eating disorders.
Women discouraged by unsuccessful treatment when they were younger should seek help again. Much more is now known about eating disorders and their treatment.
How likely is it that if a mother has an eating disorder, her daughter also will? What can parents do about this?
Parental attitude about food and their values about what constitutes a healthy weight definitely have an impact on children. It's not uncommon for mothers with eating disorders to seek help because they don't want to pass on their unhealthy attitudes about eating to their children, who also can mimic disordered eating behaviors.
As a parent, be on the lookout for warning signs of eating disorders in your children, which may include:
  • Excessive weight loss
  • Excessive exercise
  • Skipping meals
  • Being extremely fussy about food
  • Frequent trips to the bathroom after meals
  • Laxative use
Also, watch for extreme concern about shape, weight and body image. And listen to what your children are saying about issues related to food, body image, dieting and exercise. That can provide important clues about whether their own attitudes are healthy or not.
What about adult men? Don't they get eating disorders too?
Yes, males of all ages, whether adolescents or older adults, can have eating disorders, just like women of all ages. Adult men with eating disorders often have a history of being obese. They also may be striving for a more athletic or muscular build, sometimes known as reverse anorexia because they want to build broader shoulders and arms. Men are less likely than are women to engage in vomiting as a way to purge, and instead may turn more often to compulsive exercise, weight-loss supplements or weight-enhancing supplements. Like women, they also can benefit greatly with appropriate treatment.


Source : MSN.com

DAIL 999 for all emergencies in Malaysia

On call 24/7: Khirah Misni adjusting her headset while attending to a call at a TM Bhd call centre in Banda Kaaba, Malacca, on Monday. TM Bhd operates eight emergency services centres nationwide 24 hours a day, seven days a week and has 138 trained staff dedicated to handle the emergency calls.

PUTRAJAYA: It's back to 999 to report all forms of emergencies.

And callers can expect their calls to be answered within 10 seconds or after four rings.

Cellular phone users who had been dialling 112 could also dial the 999 numbers to reach the emergency call centre.

Unlike before people need not dial three sets of numbers (999, 994, 991 and 112 - for cellular phone users) to reach the different emergency and rescue service providers in the country.

Deputy Energy, Water and Communications Minister Datuk Shaziman Abu Mansor said specially-trained professionals from the 999 Emergency Call Service Centre would handle all emergency calls and reroute them, complete with digital data on the type of emergency and location.

The calls would then be handled by the respective emergency service providers like the police, ambulance, fire stations and civil defence rescue units.

Shaziman said the 999 call centre would be fully managed by Telekom Malaysia (TM) Bhd and a nationwide campaign on the use of a single number was being carried out.

“By January next year, the 991 and 994 numbers will not be used anymore, but those who still use it to call emergency service will be rerouted to the emergency call centre located throughout the country,” he told reporters during a soft launch of the single emergency number and awareness campaign called Satu Negara Satu Nombor – 999.

Shaziman said the problem of emergency calls not being answered should not arise as the unattended calls would be passed to the next available call centre.

There are a total of eight emergency call centres in the country, with the latest centre opening in Malacca.

Parallel emergency numbers, such as 991 for the Civil Defence Department and 994 for Fire and Rescue, were introduced in 1991, so that such calls could be handled directly by the departments concerned.

Before that, a single emergency number 999 was used to report all emergencies.

Shaziman said the Government decided to develop an efficient system to regroup it back to 999 after public complaints over the four emergency numbers and the many disturbing crimes in the country.

“It is not easy to remember several emergency numbers when a person is in distress. Even I am confused at times,” he said.

Wednesday, September 26, 2007

YORK Gas Furnaces

Affinity™ V Series
Affinity™ 9.M Gas Furnace

Gas Furnaces

Most home comfort systems have two parts: an outdoor air conditioner or heat pump, and an indoor unit, a furnace. Furnaces heat and circulate warm air in the winter. They also take cool air from the outdoor unit and circulate it through your home in summer. The indoor and outdoor units are designed to work together. When the furnace is properly matched with a heat pump or air conditioner, you enjoy maximum efficiency and extended system life. Furnace heating ability is measured with an Annual Fuel Utilization Efficiency (AFUE) percentage. A higher AFUE percentage indicates a more efficient furnace.

The basic components of a furnace system are:

  • A Burner, where gas (natural or propane) or oil is delivered and burned
  • A Heat Exchanger, where the heat from the burning gas is transferred to the air distribution system
  • Ductwork to transfer the heated air throughout the home
  • A Flue or Vent Pipe, to exhaust byproducts of combustion (such as water vapor and carbon dioxide) outside

Tuesday, September 25, 2007

Split System" Air Conditioners

Split System" Air Conditioners

A traditional home comfort system has two parts: an indoor unit, such as a furnace or air handler, and an outdoor unit. An air conditioner is the outdoor unit that cools air and sends it to the indoor unit for circulation through your home. Indoor and outdoor units are designed to work together. When the air conditioner is properly matched with a furnace or air handler, you get maximum efficiency and longer system life. Air conditioning and cooling efficiency is measured using a Seasonal Energy Efficiency Ratio (SEER). A higher SEER means higher energy efficiency. The latest standard for SEER is 13 (beginning January 2006).

Here's what makes it cool

A "split system" central air conditioner includes a compressor, fan, condenser coil, evaporator coil and refrigerant. The system removes heat from indoor air and transfers it outside, leaving the cooled indoor air to be recirculated. A central air conditioning system uses electricity as its power source.

The basic components of an air conditioning system are:

  • A Condensing Unit (the outdoor section)
  • A matching indoor air handler or furnace with coil
  • Ductwork to transfer the cooled air throughout the ho

Monday, September 24, 2007

Shark Attack

Kill the Shark!!!

Air Cond Malaysia : Panasonic Air Conditioners

Air Cond Malaysia : Panasonic Air Conditioners

Air Cond Malaysia : Panasonic Air Conditioners


CS-S12GKH (CU-S12GKH) (1.5 HP)

  • Inverter Technology
  • e-ion Air Purifiyng System with Patrol Sensor
  • Eco-Friendly

CS-S15GKH (CU-S15GKH) (1.75 HP)

  • Inverter Technology
  • e-ion Air Purifiyng System with Patrol Sensor
  • Eco-Friendly

Deluxe - ENVIO P2 Non Inverter

CS-C9GKH (CU-C9GKH) (1 HP)

  • e-ion Air Purifiyng System with Patrol Sensor
  • Advanced Powerful
  • Super Quiet
  • Blue Fin Condenser
  • Random Auto Restart

CS-C12GKH (CU-C12GKH) (1.5 HP)

  • e-ion Air Purifiyng System with Patrol Sensor
  • Advanced Powerful
  • Super Quiet
  • Blue Fin Condenser
  • Random Auto Restart

CS-C18GKH (CU-C18GKH) (2 HP)

  • e-ion Air Purifiyng System with Patrol Sensor
  • Advanced Powerful
  • Super Quiet
  • Blue Fin Condenser
  • Random Auto Restart

CS-C24GKH (CU-C24GKH) (2.5 HP)

  • e-ion Air Purifiyng System with Patrol Sensor
  • Advanced Powerful
  • Super Quiet
  • Blue Fin Condenser
  • Random Auto Restart

CS-C28GKH (CU-C28GKH) (3 HP)

    • e-ion Air Purifiyng System with Patrol Sensor
    • Advanced Powerful
    • Super Quiet
    • Blue Fin Condenser
    • Random Auto Restart

Standard - Wireless

CS-PC9GKH (CU-PC9GKH) (1 HP)

  • Super Alleru-Buster (Optional)
  • Blue Fin Condenser
  • Random Auto Restart
  • Wireless Remote Controller

CS-PC12GKH (CU-PC12GKH) (1.5 HP)

  • Super Alleru-Buster (Optional)
  • Blue Fin Condenser
  • Random Auto Restart
  • Wireless Remote Controller

CS-PC18DKH (CU-PC18DKH) (2 HP)

  • Super Alleru-Buster (Optional)
  • Blue Fin Condenser
  • Random Auto Restart
  • Wireless Remote Controller

CS-PC24DKH (CU-PC24DKH) (2.5 HP)

  • Super Alleru-Buster (Optional)
  • Blue Fin Condenser
  • Random Auto Restart
  • Wireless Remote Controller

CS-PC28DKH (CU-PC28DKH) (3 HP)

  • Super Alleru-Buster (Optional)
  • Blue Fin Condenser
  • Random Auto Restart
  • Wireless Remote Controller

Standard - Wired

CS-SC9GKH (CU-SC9GKH) (1 HP)

  • Super Alleru-Buster (Optional)
  • Blue Fin Condenser
  • Random Auto Restart
  • Wired Remote Controller

CS-SC12GKH (CU-PC12GKH) (1.5 HP)

  • Super Alleru-Buster (Optional)
  • Blue Fin Condenser
  • Random Auto Restart
  • Wired Remote Controller

CS-SC18DKH (CU-PC18DKH) (2 HP)

  • Super Alleru-Buster (Optional)
  • Blue Fin Condenser
  • Random Auto Restart
  • Wired Remote Controller

CS-SC24DKH (CU-PC24DKH) (2.5 HP)

  • Super Alleru-Buster (Optional)
  • Blue Fin Condenser
  • Random Auto Restart
  • Wired Remote Controller

CS-SC28DKH (CU-PC28DKH) (3 HP)

  • Super Alleru-Buster (Optional)
  • Blue Fin Condenser
  • Random Auto Restart
  • Wired Remote Controller

LG Lowest Noise Level Ceiling Cassette Type Air Conditioner Model : HT-C306HLAO



Model : HT-C306HLAO


The Lowest Noise Level Ceiling Cassette Type Air Conditioner in Malaysia

With BLCD Motor for up to 30% energy saving vs AC Motor and to reduce noise level up to 30%.




▪ CHAOS Swing
▪ Powerful Mode (Power wind)
▪ Slimmest height at 225mm
▪ Drain Pump
▪ Energy Saving Cool Operation
▪ Self Diagnosis
▪ Low Pressure Switch
▪ Low Ambient Control
▪ Soft Dry Operation
▪ Auto Operation (artificial intelligence)
▪ Auto Function
▪ Atuo Restart Operation
▪ Child Lock
▪ Forced Operation
▪ Group Control
▪ Sleep Mode